Number
Control
Indicator
Function
(1)   Parameter selection button (left)
for selecting the parameters listed below.
The corresponding indicator lights up when a parameter is selec-
ted.
     
  Material thickness *)
in mm or inches
     
Current *)
current in A
Before the start of welding, the machine automatically displays a
standard value based on the programmed parameters. During
welding, the actual value is displayed.
     
  Wire feed speed *)
in m/min or ipm
     
  Special function
can only be selected if the SP welding process and the LSC or
PMC special program has first been selected using the "Welding
process" button (5).
The following process control parameters can be selected and
adjusted on all devices:
- Penetration stabiliser
- Arc length stabiliser
As soon as F1 is selected, the current adjustable process control
parameter is marked with an arrow on the display. Press the
"Parameter selection" button (left) (1) again to select the second
process control parameter.
The following special functions can be selected depending on
the configuration.
  *) = Synergic parameter
When a synergic parameter is changed, the synergic function
automatically changes all other synergic parameters to match.
30