Loading...
Poor weld properties
Incorrect welding parameters
Check the settings
Poor ground earth connection
Ensure good contact to workpiece
Inadequate or no protective gas shield
Check the pressure regulator, gas hose, gas solenoid valve, torch gas con-
nection, etc.
Welding torch is leaking
Change the welding torch
Wrong contact tip, or contact tip is worn out
Replace the contact tip
Wrong wire alloy or wrong wire diameter
Check the wire electrode that has been inserted
Wrong wire alloy or wrong wire diameter
Check weldability of the base material
The shielding gas is not suitable for this wire alloy
Use the correct shielding gas
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
Cause:
Remedy:
60