    cassandra81Aug 6, 2025
    What to do if I can’t get any sound from the FrontRow CM900 amp?
    • C
      Carrie HallAug 6, 2025
      If you've connected FrontRow Recording Equipment and can't get any sound from the amp, first check the Master Volume settings by going to the command line and entering #AUD1[ ]; Volume Level value 0 - 100, where 100 is max. Also, check the PA Fault LED; it should not be lit. If it is lit and the device is not in mute mode, the PA may be damaged; see the LED Status information.
  • P
    Paige ArnoldAug 12, 2025
    How to reset IP address on FrontRow Recording Equipment CM900?
    • K
      Kara BartlettAug 12, 2025
      If you can't remember the IP address you changed the FrontRow CM900 to and can't communicate with it, perform a hardware reset. This will change the IP address back to the default (192.168.1.103).
  • S
    Sarah WolfeAug 18, 2025
    How to reset web access password on FrontRow Recording Equipment CM900?
    • W
      Willie LewisAug 18, 2025
      To reset the FrontRow CM900 web access password to its default ('calypso'), follow steps 1 - 5.
  • Z
    Zachary Walsh Jr.Aug 25, 2025
    What to do if FrontRow Recording Equipment CM900 cannot communicate after connection?
    • P
      Phillip FordAug 25, 2025
      If you've connected a new FrontRow CM900 to your computer for configuration but can't communicate with it, and you are using a Windows computer, clear the ARP cache. From the command prompt, enter: ARP -D IPADDRESS (e.g., ARP -D 192.168.1.104).
  • A
    Amber HernandezAug 30, 2025
    What to do if FrontRow Recording Equipment CM900 can't control the projector?
    • P
      Patricia MurphyAug 30, 2025
      If you've connected the serial cable from the FrontRow CM900 to the projector, verified that the baud rate and other settings are correct, but still can't control the projector, try switching the TX and RX wires.

Summary

Step 1: Before You Begin

Visualize Your Goal

Understand the desired classroom audio-visual setup and desired functionality.

Get Familiar with Input and Output Ports

Identify and understand the purpose of each physical connection port on the CM900 device.

What Do You Want to Control?

Plan the devices and functions the CM900 should manage within the classroom environment.

Gathering Information

Collect essential network and component details required for system configuration.

Step 2: Getting Your Configuration Files

Step 3: Preparing for Configuration

Gather Your Configuration Tools

List necessary hardware, software, and documentation for setting up the CM900.

Connect Your Configuration Setup

Detail the physical connection between the CM900 and the configuration computer.

Step 4: Configuring the CM900

Access CM900

Learn how to connect to the CM900's web interface using its IP address.

About

View device information such as MAC address, firmware version, and set device name/password.

Load;Save

Manage configuration files by loading existing settings or saving current configurations.

PA; Intercom

Configure settings for Paging, Intercom, and Push-to-Talk microphone modes.

Audio

Adjust master, auxiliary input, and output volume levels for room audio sources.

Network; COM

Configure IP addresses, subnet masks, and serial port communication settings.

Command Line

Test commands and verify device responses for troubleshooting and setup.

Shortcuts

Create name substitutions for IP addresses to simplify configuration file management.

Action Creator

Define specific instructions (actions) to be sent to devices.

Event Creator

Specify triggers and link them to actions to automate device behavior.

Appendix A: Control Commands for the CM900

Action;Network Commands

Overview of commands for controlling devices over the network.

Network (NET) Commands

Syntax and usage for network-based commands using TCP/IP or UDP.

Intercom (HTP Commands)

Commands for initiating intercom requests via HTTP URLs.

Serial (COM) Commands

Syntax for controlling devices via serial ports (COM1, COM2).

IR-Out Universal Commands

Commands for controlling devices via IR ports.

Alarm Commands

Commands for starting, stopping, and setting the duration of alarms.

Serial Commands (SACP)

Detailed commands for controlling audio via the Serial Action Control Protocol.

Appendix B: Configuration File Settings

Appendix C: Troubleshooting

Appendix D: Give Your Computer a Static IP Address

FrontRow CM900 Specifications

General IconGeneral
BrandFrontRow
ModelCM900
CategoryRecording Equipment
LanguageEnglish