EasyManuals Logo

FrontRow CM900 User Manual

FrontRow CM900
29 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #13 background imageLoading...
Page #13 background image
10
Volume
Adjusts the master volume of all the inputs together (microphones and auxiliary sources). Individual volumes can be adjusted
based on relative volume of devices or microphones. Note that this is not a permanent setting — it will change when the
volume is changed in other ways, e.g., using Teacher Edition or Encore software, or via control devices such as the CB6000, or
even the knob on a CB75.
Aux Input Volume
Adjusts the individual volumes of the auxiliary inputs. Each input can have a different volume setting. For example, a DVD
player can be set at higher volume than the teacher’s computer. Adjusting the master volume will keep the same relative
difference between the inputs.
Aux Out Volume
Adjusts the volume of the auxiliary (Line Out) audio output. This is important for lesson capture or integration with ALD’s (Assistive
Listening Devices)
Routing for Outgoing Streams
Select which audio stream is sent back to the front office. If both are selected, the combined streams will be sent.
Include sound from Intercom Streams only audio from the from the CB75 or CB85
Include sound from Ch1 Line-in Streams the audio from the audio that is coming in through Ch1, typically a teacher microphone
External Page Override
For use with 25V, 70V and 100V analog paging systems. The CM900 will mute all audio in the room when an announcement is
made over the facility’s paging system. Analog page override requires a connection to the facility’s PA system. For information
about connecting the page override function to the PA system, see Juno Page Override Installer Guide.
Sensitivity Determines how easily the page override will trigger based on the detected voltage of the paging system. If the
CM900 does not detect a page, increase sensitivity. If the CM900 triggers when there is no page, but voltage is detected,
decrease sensitivity.
PGO Release The amount of time it takes for the local (in room) audio to return to normal volume after the audio from the
paging system ends.
5. Audio
These settings affect the local audio in the room (microphones and auxiliary sources) and other device settings

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the FrontRow CM900 and is the answer not in the manual?

FrontRow CM900 Specifications

General IconGeneral
BrandFrontRow
ModelCM900
CategoryRecording Equipment
LanguageEnglish