5-10
5.3.7 Fill Vat from Drain (Filter) Pan
The drain to pan function drains the oil from the vat to the filter pan.
DISPLAY ACTION
1. The fryer MUST be OFF.
2. Press the filtration menu button
3. Select LEFT VAT or RIGHT VAT for split vats.
4. Press the down arrow.
5. Select FILL VAT FROM DRAIN PAN.
FILL VAT FROM DRAIN PAN?
6. Press the (check) button to continue. If the X button is selected, the
controller goes to OFF. If no pan is detected, the controller displays
INSERT PAN until the pan is detected.
FILLING 7. No action is required while the vat is filling.
IS VAT FULL?
8. Press the X button to run the pump again if the oil level is below the
top oil level full line. Press the (check) button once the vat is full and
to return to OFF.
9. The controller switches off.
5.3.8 Fill Vat from Bulk
The drain to pan function drains the oil from the vat to the filter pan.
DISPLAY ACTION
1. The fryer MUST be OFF.
2. Press the filtration menu button