EasyManua.ls Logo

FT FT742 - FL.1: General Filter Settings

FT FT742
66 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Section 6 Parameter Settings
45 FT742-DM (RS485) Sensors – User Manual
6.4.8 FL.1: General Filter Settings
Command
Parameter
FL (enable/ disable)
Command
Syntax
SET Sensor:
$<listenerID>,FL<filter>*<checksum><cr><lf>
$aa,FLc*hh<cr><lf>
QUERY Sensor:
$<listenerID>,FL?*<checksum><cr><lf>
$aa,FL?*hh<cr><lf>
Sensor output:
$<talkerID>,FL=<filter>*<checksum><cr><lf>
$aa,FL=c*hh<cr><lf>
Parameters
<filter>
E
Filter enabled (Factory Default Setting)
D
Filter disabled
Examples
Example 1
Enable the filter. Verify that the command has been accepted.
Message
Comment
$01,FLE*//<cr><lf>
Enable filtering
$01,FL?*//<cr><lf>
Query filter setting
$WI,FL=E*40<cr><lf>
Sensor response
Example 2
Disable the filter. Verify that the command has been accepted.
Message
Comment
$01,FLD*//<cr><lf>
Disable filtering
$01,FL?*//<cr><lf>
Query filter setting
$WI,FL=D*41<cr><lf>
Sensor response
Description
Use the FL command to enable or disable moving average filtering of the wind speed and
wind direction readings (see Section 2.3).

Table of Contents