EasyManua.ls Logo

Fuji Electric PXG-9 - Page 56

Fuji Electric PXG-9
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 54 –
7
Chapter
"
dd
dd
ii
ii
11
11
"
di1 DI-1 function select 009E
H
40143 41143 Word
0 (no function)
1 (Switches between STBY ON/OFF)
2 (Switches between Auto/Manual)
3 (Switches between Local/Remote)
4 (Switches EXMV1)
5 (no function)
6 (Starts AT (standard))
7 (Starts AT (low PV))
8 (no function)
9 (no function)
10 (no function)
11 (Ramp SV HOLD)
12 (Ramp/soak OFF)
13 (Ramp/soak RUN/HOLD)
14 (no function)
15 (Latch cancel (all))
16 (Latch cancel (DO1))
17 (Latch cancel (DO2))
18 (Latch cancel (DO3))
19 (Latch cancel (DO4))
20 (Latch cancel (DO5))
21 (Start timer (DO1))
22 (Start timer (DO2))
23 (Start timer (DO3))
24 (Start timer (DO4))
25 (Start timer (DO5))
26 (SV No. 1)
27 (SV No. 2)
28 (SV No. + 4)
29 (PID No. 1 +1)
30 (PID No. 1 +2)
31 (PID No. 1 + 4)
32 (no function)
33 (no function)
34 (no function)
35 (SV No.+1, PID No. 1+1)
36 (SV No.+2, PID No. 1+2)
37 (SV No.+4, PID No. 1+4)
0
"
dd
dd
ii
ii
22
22
"
di2 DI-2 function select 009F
H
40144 41144 Word Same as above 0
"
dd
dd
ii
ii
33
33
"
di3 DI-3 function select
00A0
H
40145 41145 Word Same as above 0
"
dd
dd
ii
ii
44
44
"
di4 DI-4 function select 00A1
H
40146 41146 Word Same as above 0
"
dd
dd
ii
ii
11
11
55
55
"
di5 DI-5 function select 00A2
H
40147 41147 Word Same as above 0
"
dd
dd
oo
oo
11
11
TT
TT
"
do1T
DO1 output event type setting
0038
H
40041 41041 Word 0-102 0
"
dd
dd
oo
oo
PP
PP
11
11
"
doP1 Sets DO1 option function 00B5
H
40166 41166 Word 0000 to 1111 0
"
dd
dd
oo
oo
22
22
TT
TT
"
do2T
DO2 output event type setting
0039
H
40042 41042 Word 0 to 102 0
"
dd
dd
oo
oo
PP
PP
22
22
"
doP2
DO5 option function setting
00BC
H
40173 41173 Word 0000 to 1111 0
"
dd
dd
oo
oo
33
33
TT
TT
"
do3T DO3 output event type
setting
003A
H
40043 41043 Word 0 to 102 0
"
dd
dd
oo
oo
PP
PP
33
33
"
doP3
DO3 option function setting
00C3
H
40180 41180 Word 0000 to 1111 0
"
dd
dd
oo
oo
44
44
TT
TT
"
do4T
DO4 output event type setting
00C6
H
40183 41183 Word 0 to 102 0
"
dd
dd
oo
oo
PP
PP
44
44
"
doP4
DO4 option function setting
00CA
H
40187 41187 Word 0000 to 1111 0
"
dd
dd
oo
oo
55
55
TT
TT
"
do5T DO5 output event type
setting
00CD
H
40190 41190 Word 0 to 102 0
"
dd
dd
oo
oo
PP
PP
55
55
"
doP5
DO5 option function setting
00D1
H
40194 41194 Word 0000 to 1111 0
"
rr
rr
MM
MM
PP
PP
LL
LL
"
rMPL Ramp SV - Decline 01C9
H
40430 41430 Word 0% to 100% FS/°C 0°C
"
rr
rr
MM
MM
PP
PP
hh
hh
"
rMPh Ramp SV ñ Incline 01CA
H
40431 41431 Word 0% to 100% FS/°C 0°C
Parameter
display
Parameter
name
Contents
Relative
address
Resistor Number
Type
Read data
Written data
range
Factory Setting
Dependent
on range
Internal
Engineering
unit

Related product manuals