Model: ACUH18LUAS1
AFR CFM 435
Indoor temperature
°FDB 60 65 70 75
Outdoor temperature
°FDB °FWB
TC IP TC IP TC IP TC IP
kBtu/h kW kBtu/h kW kBtu/h kW kBtu/h kW
-5 -7 15.75 2.02 15.38 2.06 15.00 2.10 14.25 2.18
5 3 18.38 2.11 17.94 2.16 17.50 2.20 16.63 2.29
14 12 19.95 2.36 19.48 2.41 19.00 2.46 18.05 2.56
23 19 21.68 2.60 21.16 2.66 20.10 2.71 19.61 2.82
32 28 22.84 2.92 22.30 2.98 21.76 3.04 20.67 3.16
41 37 23.44 2.51 22.88 2.56 22.33 2.61 21.21 2.71
47 43 25.10 2.40 24.50 2.45 23.90 2.50 22.71 2.60
50 47 26.15 2.25 25.52 2.29 24.90 2.34 23.66 2.42
59 50 27.20 1.99 26.55 2.04 25.90 2.08 24.61 2.15
68 59 25.84 1.60 25.34 1.63 24.61 1.66 23.37 1.73
75 64 26.38 1.64 25.88 1.67 25.12 1.70 23.87 1.77
AFR
m
3
/h
740
Indoor temperature
°CDB 15.6 18.3 21.1 23.9
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP
kW kW kW kW
-20.6 -21.7 4.62 1.20 4.51 1.23 4.40 1.25 4.18 1.30
-15.0 -16.1 5.39 1.23 5.26 1.25 5.13 1.28 4.87 1.33
-10.0 -11.1 5.85 1.31 5.71 1.33 5.57 1.36 5.29 1.41
-5.0 -7.2 6.35 1.38 6.20 1.41 5.89 1.44 5.75 1.50
0.0 -2.2 6.69 1.49 6.54 1.52 6.38 1.55 6.06 1.61
5.0 2.8 6.87 1.58 6.71 1.62 6.54 1.65 6.22 1.72
8.3 6.1 7.35 1.60 7.18 1.64 7.00 1.67 6.65 1.74
10.0 8.3 7.66 1.62 7.48 1.66 7.30 1.69 6.93 1.75
15.0 10.0 7.97 1.53 7.78 1.56 7.59 1.59 7.21 1.65
20.0 15.0 7.57 1.19 7.43 1.22 7.21 1.24 6.85 1.29
24.0 18.0 7.73 1.25 7.58 1.27 7.36 1.30 6.99 1.35
- 10 -
4-2. Heating capacity 4. Capacity table
CASSETTE TYPE
ADUH09-18LUAS1
CASSETTE TYPE
ADUH09-18LUAS1