4-2. Heating capacity
NOTE: Values mentioned in the table are calculated based on the maximum capacity.
¢
Model: ACUH09LUAS1
AFR CFM 318
Indoor temperature
°FDB 60 65 70 75
Outdoor temperature
°FDB °FWB
TC IP TC IP TC IP TC IP
kBtu/h kW kBtu/h kW kBtu/h kW kBtu/h kW
-5 -7 8.96 1.18 8.74 1.21 8.53 1.23 8.10 1.28
5 3 10.63 1.28 10.37 1.30 10.12 1.33 9.61 1.38
14 12 10.47 1.31 10.22 1.33 9.97 1.36 9.47 1.41
23 19 12.32 1.38 12.02 1.41 11.73 1.44 11.14 1.50
32 28 13.99 1.49 13.65 1.52 13.32 1.55 12.65 1.61
41 37 15.49 1.58 15.12 1.62 14.75 1.65 14.01 1.72
47 43 16.80 1.65 16.40 1.69 16.00 1.72 15.20 1.79
50 47 16.89 1.67 16.49 1.71 16.09 1.74 15.29 1.80
59 50 17.06 1.57 16.66 1.60 16.25 1.64 15.44 1.69
68 59 16.10 1.19 15.79 1.22 15.33 1.24 14.56 1.29
75 64 16.62 1.25 16.30 1.27 15.83 1.30 15.04 1.35
AFR
m
3
/h
540
Indoor temperature
°CDB 15.6 18.3 21.1 23.9
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP
kW kW kW kW
-20.6 -21.7 2.63 1.20 2.56 1.23 2.50 1.25 2.38 1.30
-15.0 -16.1 3.11 1.23 3.04 1.25 2.97 1.28 2.82 1.33
-10.0 -11.1 3.07 1.31 3.00 1.33 2.92 1.36 2.78 1.41
-5.0 -7.2 3.61 1.38 3.52 1.41 3.44 1.44 3.27 1.50
0.0 -2.2 4.10 1.49 4.00 1.52 3.90 1.55 3.71 1.61
5.0 2.8 4.54 1.58 4.43 1.62 4.32 1.65 4.11 1.72
8.3 6.1 4.92 1.60 4.81 1.64 4.69 1.67 4.45 1.74
10.0 8.3 4.95 1.62 4.83 1.66 4.72 1.69 4.48 1.75
15.0 10.0 5.00 1.53 4.88 1.56 4.76 1.59 4.52 1.65
20.0 15.0 4.72 1.19 4.63 1.22 4.49 1.24 4.27 1.29
24.0 18.0 4.87 1.25 4.78 1.27 4.64 1.30 4.41 1.35
¢
Model: ACUH12LUAS1
AFR CFM 359
Indoor temperature
°FDB 60 65 70 75
Outdoor temperature
°FDB °FWB
TC IP TC IP TC IP TC IP
kBtu/h kW kBtu/h kW kBtu/h kW kBtu/h kW
-5 -7 15.75 2.11 15.38 2.16 15.00 2.20 14.25 2.29
5 3 16.80 2.16 16.40 2.21 16.00 2.25 15.20 2.34
14 12 18.27 2.04 17.84 2.08 17.40 2.12 16.53 2.20
23 19 19.11 1.87 18.66 1.91 18.20 1.95 17.29 2.03
32 28 19.43 1.82 18.96 1.86 18.50 1.90 17.58 1.98
41 37 19.74 1.77 19.27 1.81 18.80 1.84 17.86 1.92
47 43 20.37 1.72 19.89 1.75 19.40 1.79 18.43 1.86
50 47 22.47 1.71 21.94 1.75 21.40 1.78 20.33 1.84
59 50 23.31 1.51 22.76 1.55 22.20 1.58 21.09 1.63
68 59 22.14 1.21 21.72 1.24 21.09 1.26 20.04 1.31
75 64 22.61 1.24 22.18 1.27 21.53 1.29 20.46 1.35
AFR
m
3
/h
610
Indoor temperature
°CDB 15.6 18.3 21.1 23.9
Outdoor temperature
°CDB °CWB
TC IP TC IP TC IP TC IP
kW kW kW kW
-20.6 -21.7 4.62 1.20 4.51 1.23 4.40 1.25 4.18 1.30
-15.0 -16.1 4.92 1.23 4.81 1.25 4.69 1.28 4.45 1.33
-10.0 -11.1 5.35 1.31 5.23 1.33 5.10 1.36 4.84 1.41
-5.0 -7.2 5.60 1.38 5.47 1.41 5.33 1.44 5.07 1.50
0.0 -2.2 5.69 1.49 5.56 1.52 5.42 1.55 5.15 1.61
5.0 2.8 5.79 1.58 5.65 1.62 5.51 1.65 5.23 1.72
8.3 6.1 5.97 1.60 5.83 1.64 5.69 1.67 5.40 1.74
10.0 8.3 6.59 1.62 6.43 1.66 6.27 1.69 5.96 1.75
15.0 10.0 6.83 1.53 6.67 1.56 6.51 1.59 6.18 1.65
20.0 15.0 6.49 1.19 6.37 1.22 6.18 1.24 5.87 1.29
24.0 18.0 6.63 1.25 6.50 1.27 6.31 1.30 6.00 1.35
- 9 -
4-2. Heating capacity 4. Capacity table
CASSETTE TYPE
ADUH09-18LUAS1
CASSETTE TYPE
ADUH09-18LUAS1