Page #41 background image
¢
External heater output
Control Primary heater Auxiliary heater
Function setting
Indoor unit
Control switching
external heaters No. 61
Auxiliary heater control 1 Heat pump
External device*
1
61-00
Auxiliary heater control 2 Heat pump External device 61-01
Heat pump prohibition
control
External device None 61-02
Auxiliary heater control by
outdoor temperature 1
Heat pump External device 61-03
Auxiliary heater control by
outdoor temperature 2
Heat Pump External device 61-04
Auxiliary heater control by
outdoor temperature 3
Heat Pump External device 61-05
Auxiliary heat pump
control
External device Heat pump 61-06
Auxiliary heat pump
control by outdoor
temperature 1
External device Heat pump 61-07
Auxiliary heat pump
control by outdoor
temperature 2
External device Heat pump 61-08
Auxiliary heat pump
control by outdoor
temperature 3
External device Heat pump 61-09
NOTES:
After turning off the heater, 3 minutes of standby time is required by next power-on of the
heater.
For items marked “—” in the table, any of validate or invalidate of the setting are acceptable.
*1: External device means Hot water, Electrical heater, etc.
- 37 -
8-4. Details of function 8. External input and output
CASSETTE TYPE
ADUH09-18LUAS1
CASSETTE TYPE
ADUH09-18LUAS1

Table of Contents

Other manuals for Fujitsu ACUH09LUAS1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ACUH09LUAS1 and is the answer not in the manual?

Fujitsu ACUH09LUAS1 Specifications

General IconGeneral
BrandFujitsu
ModelACUH09LUAS1
CategoryAir Conditioner
LanguageEnglish

Related product manuals