6. SYSTEM DESIGN
DIP SWITCH 1 SETTING
SW1 setting forbidden
(
...Factory setting)
SW1
OFF Fixed at OFF
ON Setting forbidden
SW2 setting
Dual remote controller setting
Set the remote controller SW2 according to the following table.
(
...Factory setting)
Number
of remote
controller
Primary unit
Secondary
unit
SW2 SW2
1 (Normal) OFF -
2 (Dual) OFF ON
SW3 setting forbidden
(
...Factory setting)
SW3
OFF Fixed at OFF
ON Setting forbidden
SW4 setting
°F / °C switch
Temperature display is Fahrenheit(°F) / Celsius(°C)
(
...Factory setting)
SW4
OFF °C
ON °F
1 231 23
1 2 3
Indoor unit
Remote controller cable
Primary unit
Secondary
unit
Remote controller
- (06 - 75) -
SYSTEM
DESIGN
SYSTEM
DESIGN