- (01 - 24) -
WALL MOUNTED TYPE
ASU9-15RLS3
WALL MOUNTED TYPE
ASU9-15RLS3
EXTERNAL OUTPUT10-2.
OPERATION STATUS OUTPUT
An air conditioner operation status signal can be output.
Circuit diagram example
z
* Make the distance from the PC board to the connected unit within 10m.
Relay spec. : Max.24VDC, 10mA to less than 500mA.
Field supplyOptional parts
Ex.)Display
Indoor
control PC board Communication kit Connected unit
Ex.)Relay unit
1
2
Signal
Relay
power
supply
V
Connector
*33ft. (10m)
24V DC
ON
OFF
Operation
Stop
Indoor unit
Output signal
Parts (Optional)
z
Parts name
Model name
External connect kit UTY-XWZ X Z5
Communication kit UTY-T WBXF1
* For operating the EXTERNAL function, the wall mounted type requires the communication kit in addition to the wire
(UT Y-XWZXZ5).
Wire (External output) : UTY-XWZXZ5