- (02 - 09) -
OUTDOOR UNIT
AOU9-15RLS3
OUTDOOR UNIT
AOU9-15RLS3
ADDITIONAL CHARGE CALCULATION6.
MODEL
: AOU9RLS3, AOU12RLS3
REFRIGERANT CHARGE
z
MODEL
: AOU15RLS3
REFRIGERANT CHARGE
z
Refrigerant type R410A
Refrigerant amount
lbs. oz. 2lbs.14oz.
g 1,300
Pipe length
ft. 49 or less 66 (MAX)
0.22oz./ft.
(20g/m)
m 15 or less 20 (MAX)
Additional charge
oz. 0 +3.5
g 0 +100
Refrigerant type R410A
Refrigerant amount
lbs. oz. 3lbs.1oz.
g 1,400
Pipe length
ft. 49 or less 66 (MAX)
0.22oz./ft.
(20g/m)
m 15 or less 20 (MAX)
Additional charge
oz.
0
+3.5
g 0 +100