EasyManuals Logo

Fujitsu AOYG09KHCAN User Manual

Fujitsu AOYG09KHCAN
128 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
Check point 4. Check output voltage of main PCB
Check outdoor unit circuit diagram and the voltage. (Measure at main PCB side con-
nector)
1
2
3
4
5
6
7
BLACK
WHITE
YELLOW
RED
FM
FAN MOTOR
BROWN
NOTE:
For details of wiring diagram, refer to "Wiring diagrams" in Chapter 2.
TECHNICAL DATA AND PARTS LIST.
Read wire
DC voltage
Red—Black 240—400 V
White—Black 13.5—16.5 V
-> If the voltage is not correct, replace Main PCB.
End