1-5. Compressor frequency limitation by outdoor temperature
The minimum compressor frequency is limited by outdoor temperature as below.
Cooling/Dry mode
F zone
38°C
E zone
19°C
D zone
10°C
C zone
B zone
A zone
0°C
-10°C
Model name Outdoor temperature zone
Limitation of compressor
frequency
AOYG09KHCAN
AOYG12KHCAN
AOYG14KHCAN
A zone 18 rps
B zone 18 rps
C zone 18 rps
D zone 1 rps
E zone 1 rps
F zone 22 rps
Heating mode
F zone
19°C
E zone
5°C
D zone
0°C
C zone
B zone
A zone
-15°C
-25°C
Model name Outdoor temperature zone
Limitation of compressor
frequency
AOYG09KHCAN
AOYG12KHCAN
AOYG14KHCAN
A zone 39 rps
B zone 39 rps
C zone 17 rps
D zone 10 rps
E zone 1 rps
F zone 1 rps