3. Fan control
Tr: Room temperature
Ts: Setting temperature
3-1. Indoor fan control
¢ Fan speed
Indoor fan speed is defined as below.
Operation mode Fan mode
Speed (rpm)
ASYG09KHCA
ASYG12KHCA
ASYG14KHCA
Heating
POWERFUL 1,320 1,370
HIGH 1,100 1,210
MED+ 1,040 1,140
MED 940 1,040
LOW 820 880
QUIET 600 740
Cool air prevention 600 600
S-LOW 540 540
Cooling/Fan
POWERFUL 1,320 1,370
HIGH 1,100 1,210
MED 940 1,040
LOW 820 880
QUIET 600 680
Soft quiet
540*
1
600*
1
S-LOW
540*
2
540*
2
Dry
X zone: 600
J zone: 600
X zone: 680
J zone: 640
*1: Fan mode only
*2: Cooling mode only
¢ Fan operation
Airflow can be switched in 5 steps such as AUTO, QUIET, LOW, MED, HIGH while indoor unit fan
only runs.
When fan mode is set at AUTO, it operates on MED fan speed.
3-1. Indoor fan control
- (04-8) - 3. Fan control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS