EasyManua.ls Logo

Fujitsu ASTG30KMTC - Compressor Frequency Control; Auto Changeover Operation

Fujitsu ASTG30KMTC
199 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CONTENTS
4. CONTROL AND FUNCTIONS
1. Compressor frequency control..................................................................04-1
1-1. Cooling operation ...........................................................................................................04-1
1-2. Heating operation ...........................................................................................................04-2
1-3. Dry operation..................................................................................................................04-3
1-4. Compressor frequency at normal start-up ......................................................................04-3
2. Auto changeover operation........................................................................04-6
3. Fan control...................................................................................................04-8
3-1. Indoor fan control............................................................................................................04-8
3-2. Outdoor fan control.......................................................................................................04-11
4. Louver control ...........................................................................................04-13
4-1. Vertical airflow direction louver control .........................................................................04-13
4-2. Horizontal airflow direction louver control .....................................................................04-13
4-3. Swing operation............................................................................................................04-14
5. Timer operation control ............................................................................04-15
5-1. Wireless remote control................................................................................................04-15
6. Defrost operation control .........................................................................04-17
6-1. Defrost operation in heating operation stopped ............................................................04-19
7. Various control..........................................................................................04-20
7-1. Auto restart...................................................................................................................04-20
7-2. Test operation control...................................................................................................04-20
7-3. MANUAL AUTO operation............................................................................................04-20
7-4. Forced cooling operation ..............................................................................................04-21
7-5. 10 °C HEAT operation..................................................................................................04-21
7-6. ECONOMY operation ...................................................................................................04-21
7-7. POWERFUL operation .................................................................................................04-21
7-8. Compressor preheating ................................................................................................04-22
7-9. Electronic expansion valve control ...............................................................................04-22
7-10. Prevention to restart for 3 minutes (3 minutes st) .......................................................04-22
7-11. 4-way valve control.....................................................................................................04-23
7-12. Demand response operation ......................................................................................04-23
7-13. Human sensor for energy saving................................................................................04-24
7-14. Peak cut operation (for 34 model) ..............................................................................04-25
7-15. Outdoor unit low noise operation (for 34 model).........................................................04-25
8. Various protections...................................................................................04-26
8-1. Discharge gas temperature over-rise prevention control ..............................................04-26
8-2. Anti-freezing control (cooling and dry mode) ................................................................04-26
8-3. Current release control .................................................................................................04-26
8-4. Cooling pressure over-rise protection...........................................................................04-27
8-5. Compressor temperature protection .............................................................................04-28
8-6. High pressure protection ..............................................................................................04-28

Table of Contents