¢ Model: AOTG34KMTC
Unit: A
• Cooling
Outdoor temp. (Ta)
Outdoor unit fan speed (rpm)
950 890 800 780 690 520 390 330 300 270 250
50°C ≤ Ta 12.5/12.0 6.5/6.0
5.0/4.5
46°C ≤ Ta < 50°C 13.5/13.0 9.0/8.5
40°C ≤ Ta < 46°C 16.5/16.0 10.0/9.5 9.0/
8.5
6.0/5.5
38°C ≤ Ta < 40°C
19.5/19.0
17.5
/17.0
13.5
/13.0
10.0
/9.5
31°C ≤ Ta < 38°C
14.5
/14.0
19°C ≤ Ta < 31°C
19.0
/18.5
15.5
/14.5
11.0
/10.5
10.0
/9.5
13°C ≤ Ta < 19°C
15.5
/15.0
10.5
/10.0
7°C ≤ Ta < 13°C
13.5
/13.0
0°C ≤ Ta < 7°C
16.5/15.5
12.5
/12.0
-5°C ≤ Ta < 0°C 14.5/14.0
12.0
/11.5
10.0
/9.5
-10°C ≤ Ta < -5°C 15.5/15.0
11.5
/11.0
-15°C ≤ Ta < -10°C
16.5/16.0
12.5/12.0
8.0
/7.5
Ta < -15°C 13.0/12.5
Trigger condition/Release condition
• Heating
Outdoor temp. (Ta)
Outdoor unit fan speed (rpm)
950 890 800 780 690 520 410 280 250
20°C ≤ Ta 14.5/14.0
12°C ≤ Ta < 20°C 16.5/16.0
Ta < 12°C 19.5/19.0 16.5/16.0
Trigger condition/Release condition
8-4. Cooling pressure over-rise protection
When the outdoor unit heat exchanger temperature reaches trigger condition below, the compressor
is stopped and trouble display is performed.
Trigger condition
30 model 65°C
34 model 68°C
8-3. Current release control - (04-27) - 8. Various protections
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS