7-4. Forced cooling operation
When FORCED COOLING OPERATION button is pressed more than 10 seconds, forced cooling
operation starts as shown in the table below.
Operation mode Cooling
Fan mode HIGH
Timer mode Continuous (no timer setting available)
Setting temperature 24°C
Vertical airflow direction louver setting Standard
Horizontal airflow direction louver setting According to memory position
SWING Off
ECONOMY Off
Human sensor Off
During the forced cooling operation, it operates regardless of room temperature sensor.
Operation LED and timer LED blink at the same time during the forced cooling operation.
They blink for 1 second ON and 1 second OFF on both operation LED and timer LED (same as
test operation).
Forced cooling operation is released after 60 minutes of starting operation or pressing FORCED
COOLING OPERATION button for 3 seconds.
7-5. 10 °C HEAT operation
10 °C HEAT operation performs as below setting when pressing 10 °C HEAT button.
Operation mode Heating
Setting temperature 10°C
Fan mode AUTO
LED display Economy
Defrost operation Operate as normal
7-6. ECONOMY operation
The ECONOMY operation starts by pressing ECONOMY button on the remote controller.
The ECONOMY operation is almost the same operation as below settings.
Mode Cooling/Dry Heating
Target temperature Setting temperature +1°C Setting temperature -1°C
7-7. POWERFUL operation
The POWERFUL operation starts by pressing POWERFUL button on the remote controller.
The indoor unit and outdoor unit operate at maximum power as shown in the table below.
Compressor frequency Maximum
Fan mode POWERFUL
Vertical airflow direction
louver setting
Cooling
3
Dry
Heating 5
Release condition:
Cooling/Dry
Room temperature ≤ Setting temperature -0.5°C or Operation time has passed 20 minutes.
Heating
Room temperature ≥ Setting temperature +0.5°C or Operation time has passed 20 minutes.
7-4. Forced cooling operation - (04-21) - 7. Various control
CONTROL AND
FUNCTIONS
CONTROL AND
FUNCTIONS

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu ASTG30KMTC and is the answer not in the manual?

Fujitsu ASTG30KMTC Specifications

General IconGeneral
BrandFujitsu
ModelASTG30KMTC
CategoryAir Conditioner
LanguageEnglish

Related product manuals