Model: AOTG34KMTC
Fan speed is defined by outdoor temperature and compressor frequency.
Unit: rpm
Cooling or dry Heating
950 950
890 890
800 800
780 780
690 690
520 520
390 410
330 280
300 250
270 —
250 —
• When the compressor frequency increases, the outdoor fan speed also changes to the higher
speed.
•
When the compressor frequency decreases, the outdoor fan speed also changes to the lower
speed.
NOTE: After defrost control on the heating mode, the fan speed is kept higher regardless of the
compressor frequency.
Fan speed after defrost control: 950 rpm
3-2. Outdoor fan control - (04-12) - 3. Fan control
CONTROL AND
FUNCTIONS
CONTROL AND