Type Inverter, Heat pump
Model name AOUH30LUAS1 AOUH36LUAS1
Power supply 208/230 V~ 60 Hz
Power supply intake Outdoor unit
Available voltage range 187—253 V
Starting current A 13.4 16.5
Fan
Airflow rate
Cooling
CFM (m
3
/h)
2,301 (3,910) 2,502 (4,250)
Heating 2,219 (3,770) 2,431 (4,130)
Type × Qty Propeller fan × 1
Motor output → 120
Sound pressure level*
Cooling
dB (A)
53 54
Heating 55 56
Heat exchanger type
Dimensions
(H × → × D)
in (mm)
Main 1: 38-1/16 × 35-5/8 × 11/16
(966 × 905 × 18.19)
Main 2: 38-1/16 × 35-5/8 × 11/16
(966 × 905 × 18.19)
Fin pitch FPI
Main 1: 18
Main 2: 18
Rows × Stages
Main 1: 1 × 46
Main 2: 1 × 46
Pipe type Copper tube
Fin type
Type (Material) Aluminum
Surface treatment Blue fin
Compressor
Type DC twin rotary
Motor output → 1,830
Refrigerant
Type R410A
Charge
lb oz 5 lb 8 oz
g 2,500
Refrigerant oil
Type POE (RB68)
Amount
in
3
(cm
3
)
48.8 (800)
Enclosure
Material Steel sheet
Color
Beige
Approximate color of Munsell 10↔R 7.5/1.0
Dimensions
(H × → × D)
Net
in (mm)
39-5/16 × 37 × 12-5/8
(998 × 940 × 320)
Gross
46-5/16 × 40-7/16 × 17-1/2
(1,176 × 1,027 × 445)
→eight
Net
lb (kg)
139 (63)
Gross 159 (72)
Connection pipe
Size
Liquid
in (mm)
Ø3/8 (Ø9.52)
Gas Ø5/8 (Ø15.88)
Method Flare
Pre-charge length
ft (m)
66 (20)
Max. length 164 (50)
Max. height difference 98 (30)
Operation range
Cooling
°F (°C)
-5 to 115 (-21 to 46)
Heating -5 to 75 (-21 to 24)
Drain hose
Material LDPE
Tip diameter in (mm)
Ø1/2 (Ø13.0) (I.D.)
Ø5/8 to Ø11/16 (Ø16.0 to Ø16.7) (O.D.)
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80°FDB (26.67°CDB)/67°F→B (19.44°C→B), and outdoor temperature of 95°FDB (35°CDB)/75°F→B (23.9°C→B).
– Heating: Indoor temperature of 70°FDB (21.11°CDB)/60°F→B (15.56°C→B), and outdoor temperature of 47°FDB (8.33°CDB)/43°F→B (6.11°C→B).
– Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *: Sound pressure level
– Measured values in manufacturer’s anechoic chamber.
– Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
1-2. Outdoor unit - (01-6) - 1. Specifications