Heating mode
F zone
E zone
D zone
C zone
B zone
A zone
G zone
H zone
I zone
35.6°F
(2°C)
68.0°F
(20°C)
60.8°F
(16°C)
53.6°F
(12°C)
44.6°F
(7°C)
19.4°F
(-7°C)
5.0°F
(-15°C)
14.0°F
(-10°C)
Unit: rps
Model name Outdoor temperature zone
Limitation of compressor
frequency
AOUH24LUAS1
A zone 71
B zone 53
C zone 44
D zone 39
E zone 29
F zone 23
G zone 23
H zone 23
I zone 21
AOUH30LUAS1
AOUH36LUAS1
A zone 55
B zone 51
C zone 42
D zone 39
E zone 28
F zone 24
G zone 21
H zone 16
I zone 20
1-5. Rotation number of compressor limitation by outdoor temperature - (04-10) - 1. Rotation number control of compressor