En-17
Room temperature control for indoor unit sensor
Depending on the installed environment, correction of the room temperature sensor may
be required.
Select the appropriate control setting according to the installed environment.
The temperature correction values show the difference from the “Standard setting” (00)
(manufacturer’s recommended value).
(... Factory setting)
Function number
Setting
value
Setting description
30
(For cooling)
31
(For heating)
00 Standard setting
01 No correction 0.0 °C (0 °F)
02 -0.5 °C (-1 °F)
More
Cooling
Less
Heating
03 -1.0 °C (-2 °F)
04 -1.5 °C (-3 °F)
05 -2.0 °C (-4 °F)
06 -2.5 °C (-5 °F)
07 -3.0 °C (-6 °F)
08 -3.5 °C (-7 °F)
09 -4.0 °C (-8 °F)
10 +0.5 °C (+1 °F)
Less
Cooling
More
Heating
11 +1.0 °C (+2 °F)
12 +1.5 °C (+3 °F)
13 +2.0 °C (+4 °F)
14 +2.5 °C (+5 °F)
15 +3.0 °C (+6 °F)
16 +3.5 °C (+7 °F)
17 +4.0 °C (+8 °F)
Room temperature control for wired remote controller sensor
Depending on the installed environment, correction of the wire remote temperature sensor
may be required.
Select the appropriate control setting according to the installed environment.
To change this setting, set Function 42 to “Both” (01).
Ensure that the Thermo Sensor icon is displayed on the remote controller screen.
(... Factory setting)
Function number
Setting
value
Setting description
35
(For cooling)
36
(For heating)
00 No correction
01 No correction 0.0 °C (0 °F)
02 -0.5 °C (-1 °F)
More
Cooling
Less
Heating
03 -1.0 °C (-2 °F)
04 -1.5 °C (-3 °F)
05 -2.0 °C (-4 °F)
06 -2.5 °C (-5 °F)
07 -3.0 °C (-6 °F)
08 -3.5 °C (-7 °F)
09 -4.0 °C (-8 °F)
10 +0.5 °C (+1 °F)
Less
Cooling
More
Heating
11 +1.0 °C (+2 °F)
12 +1.5 °C (+3 °F)
13 +2.0 °C (+4 °F)
14 +2.5 °C (+5 °F)
15 +3.0 °C (+6 °F)
16 +3.5 °C (+7 °F)
17 +4.0 °C (+8 °F)
Auto restart
Enable or disable automatic restart after a power interruption.
(... Factory setting)
Function
number
Setting
value
Setting description
40
00 Enable
01 Disable
* Auto restart is an emergency function such as for power outage etc. Do not attempt to
use this function in normal operation. Be sure to operate the unit by remote controller or
external device.
Room temperature sensor switching
(Only for wireless remote controller)
When using the Wired remote controller temperature sensor, change the setting to “Both” (01).
(... Factory setting)
Function
number
Setting
value
Setting description
42
00 Indoor unit
01 Both
00: Sensor on the indoor unit is active.
01: Sensors on both indoor unit and wired remote controller are active.
*
Remote controller sensor must be turned on by using the remote controller
Remote controller custom code
(Only for wireless remote controller)
The indoor unit custom code can be changed. Select the appropriate custom code.
(... Factory setting)
Function
number
Setting
value
Setting description
44
00 A
01 B
02 C
03 D
External input control
“Operation/Stop” mode or “Forced stop” mode can be selected.
(... Factory setting)
Function num-
ber
Setting
value
Setting description
46
00 Operation/Stop mode 1
01 (Setting prohibited)
02 Forced stop mode
03 Operation/Stop mode 2
Room temperature sensor switching (Aux.)
To use the temperature sensor on the wired remote controller only, change the setting to “Wired
remote controller” (01). This function will only work if the function setting 42 is set at “Both” (01)
(... Factory setting)
Function num-
ber
Setting
value
Setting description
48
00 Both
01 Wired remote controller
Indoor unit fan control for energy saving for cooling
Enables or disables the power-saving function by controlling the indoor unit fan rotation when
the outdoor unit is stopped during cooling operation.
(... Factory setting)
Function num-
ber
Setting
value
Setting description
49
00 Disable
01 Enable
02 Remote controller
00: When the outdoor unit is stopped, the indoor unit fan operates continuously following
the setting on the remote controller.
01: When the outdoor unit is stopped, the indoor unit fan operates intermittently at a very
low speed.
02: Enable or disable this function by remote controller setting.
*When using a wired remote controller without Indoor unit fan control for energy saving for
cooling function, or when connecting a single split converter, the setting cannot be made
by using the remote controller. Set to (00) or (01).
To con rm if the remote controller has this function, refer to the operating manual of each
remote controller.
Switching functions for external output terminal
Functions of the external output terminal can be switched.
(... Factory setting)
Function num-
ber
Setting
value
Setting description
60
00 Operation status
01 to 08 (Setting prohibited)
09 Error status
10 Fresh air control
11 Auxiliary heater
9379124119-03_IM.indb 179379124119-03_IM.indb 17 2019/2/22 16:51:382019/2/22 16:51:38