Operation
Notes on power management
If your computer is equipped with power managem ent ( power-saving m ode), the monitor can fully
support this function. Here the monitor does not di stinguish b etween the individual energy-saving
modes of the computer (standby mode, suspend mode and OFF mode), as it is capable of
immediately switching into t he mode with the highest energy-saving effect.
Stage Operation
Power saving mode
Normal
ECO
Power su pply
indicator
Lights up blue illuminated green
orange
Display Max. brightness
typ. 200 cd/m
2
unlit
Power consumption
(typical)
< 28 W (B22W–6 LED)
< 25 W (B19–6 LED)
< 22 W (B22W–6 LED)
< 19 W (B19–6 LED)
reduced to ≤ 0.5 W
reduced to ≤ 0.1 W
If yo ur computer det
ects inactivity (no input) it sends an appropriate signal to the monitor to
reduce the powe r con
sumption (energy-saving mode). The power indicator of the monitor changes
colour to indicate
the status change. ECO mode is the preset factory default.
Once an input is mad
e at the computer the screen contents are restored.
For detailed info
rmation on how energy-saving mode operates, please refer to
the operating man
ual or technical manual of the computer.
Changing the monitor settings
When pu tting the monitor into operation for the first time, the screen display should
be optimally adapted to the display ada pter used.
20 Fujitsu Technology Solutions