EasyManuals Logo

Fujitsu D3231-S User Manual

Fujitsu D3231-S
98 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
a
g
e
5
Page
TechNotes D323x-S_D3243-S V1.2 Page 56 of 98 http://www.fujitsu.com/fts/products/computing/pc/accessories/mainboards
mainboards
System Monitoring
4.13
BMC BIOS Default Settings D3243-S
The default system monitoring settings like fan speed, sensor influence, and Alert temperatures are fixed by the system BIOS.
All relevant settings can be customized by system builders via the SilentFanConfig-Manager tool kit.
Sensors
PECI (Processor)
Super I/O
MCard
PCH
VCore
Graphics
Fan1 (CPU)
X
X
Fan2
X
X
X
X
X
Fan3
X
X
X
X
X
Fan4/PSU
X
X
X
X
X
“X” indicates that this specific sensor influences the speed of this specific fan
StartUp
1)
FullSpeed
2)
Alert
3)
Note
PECI (Processor)
72
89
89
These settings are fixed by the BIOS (depends on the
individual installed processor) and cannot be changed via
SilentFanConfig-Manager.
Super I/O
50°C
65°C
70°C
These settings are implemented for the current
BIOS version and may be changed for upcoming
BIOS versions!
Default minimum fan speed = 30% (all fans).
MCard
50°C
65°C
70°C
PCH
55°C
70°C
80°C
VCore
60°C
75°C
80°C
Graphics
50°C
65°C
70°C
4) If the sensor temperature is below “StartUp” the fan rotates a its defined minimum fan speed
5) Between “StartUp” and “FullSpeed” the fan speed increases linear
6) If the sensor temperature achieves Alert”, the system can provide a warning (e.g. via SystemGuard tool)

Table of Contents

Other manuals for Fujitsu D3231-S

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu D3231-S and is the answer not in the manual?

Fujitsu D3231-S Specifications

General IconGeneral
BrandFujitsu
ModelD3231-S
CategoryMotherboard
LanguageEnglish

Related product manuals