58 D3320 - BIOS Setup Utility BX2560 M2
Yes
The iRMC default values are loaded when you choose Save
Changes and Exit to exit the BIOS setup utility. Any BIOS setup
utility settings that affect the iRMC are not lost by this setting. They
are sent to the iRMC after the iRMC default values are loaded and
therefore overwrite the corresponding values again.
The setting is automatically set to No after the default values are
loaded.
Power Failure Recovery
Specifies the system restart behavior after a power failure.
Always Off
The system performs a status check and then switches off.
Previous State
The system performs a status check and then returns the mode it
was in before the power failure occurred (On or Off).
Always On
The system performs a status check and then switches on.
For the UPS scheduled operation, set it to Always On. Otherwise,
the server may not be turned on at the set time.
I All wake up sources are reconfigured during the short initialization
process. The system can be woken up via LAN etc.
Serial Multiplexer
Specifies whether the serial interface can be used by the system.
System
The serial interface can be used by the system or the operating
system.
iRMC
The serial interface can only be used by the iRMC. The operating
system cannot use this serial interface.