EasyManua.ls Logo

Fujitsu ETERNUS AX Series - Hot-Adding Disk Shelves with IOM12 Modules; Requirements for Hot-Adding Disk Shelves with IOM12 Modules; Considerations for Hot-Adding Disk Shelves with IOM12 Modules

Fujitsu ETERNUS AX Series
55 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
|Hot-adding disk shelves with IOM12 modules|
Hot-adding disk shelves with IOM12 modules
You can hot-add one or more disk shelves with IOM12 modules to an existing stack of disk shelves with IOM12
modules or hot-add a stack of one or more disk shelves with IOM12 modules directly to a SAS HBA or an
onboard SAS port on the controller.
Requirements for hot-adding disk shelves with IOM12 modules
Your system must meet certain requirements before hot-adding disk shelves with IOM12 modules.
State of your system
Your system and version of ETERNUS AX/HX Series must support the disk shelves you are hot-adding,
including the IOMs, disk drives, and SAS cables.
Your system must have less than the maximum number of disk drives supported, by at least the number of
disk shelves you plan to hot-add.
You cannot have exceeded the maximum number of disk drives supported for your system after hot-adding
disk shelves.
If you are hot-adding a stack of one or more disk shelves (directly to the platform controllers), your system
must have enough available PCI SAS HBA or onboard SAS ports or a combination of both.
Note: If you need to install an additional PCI SAS HBA, the best practice is to use 12Gb SAS HBAs to keep
controller-to-stack connectivity at 12Gbs for maximum performance. Using 6Gb SAS HBAs or a combination
of 6Gb SAS HBAs and 12Gb SAS HBAs is supported; however, IOM12 module connections to 6Gb SAS HBAs
are negotiated down to 6Gbs, resulting in lower performance.
Your system cannot have any SAS cabling error messages.
You must correct any cabling errors using the corrective actions provided by the error messages.
Using mini-SAS HD SAS optical cables
If you are using mini-SAS HD SAS optical cables or a mix of mini-SAS HD SAS optical cables and SAS copper
cables in the stack of disk shelves, you must have met the rules in the “Mini-SAS HD SAS optical cable
rules” section.
If you are hot-adding a disk shelf with mini-SAS HD SAS optical cables to a stack of disk shelves that is
connected with SAS copper cables, you can temporarily have both cable types in the stack.
After hot-adding the disk shelf, you must replace the SAS copper cables for the rest of the shelf-to-shelf
connections in the stack and the controller-to-stack connections so that the stack meets the rules in the
“Mini-SAS HD SAS optical cable rules” section. This means that you must have ordered the appropriate
number of mini-SAS HD SAS optical cables.
Considerations for hot-adding disk shelves with IOM12 modules
You should familiarize yourself with aspects and best practices about this procedure before hot-adding disk
shelves.
General considerations
If you are hot-adding a disk shelf with IOM12 modules to an existing stack (of disk shelves with IOM12
modules), you can hot-add the disk shelf to either end—the logical first or last disk shelf—of the stack.
For HX2000 systems single-path HA and single-path configurations, you hot-add disk shelves to the end of
the stack that does not have controller connections.
You can hot-add a stack of disk shelves with IOM12 modules to a system that has existing stacks of disk
shelves with IOM6 and IOM3 modules.
10