Table 2 shows details about LEDs and the status of a power synchronized unit.
Table 2 Status and meanings of each LED (for power synchronized units)
LED name Function
LED
status
Power synchronized unit status
POWER
(green)
Displays the power sta-
tus of the power syn-
chronized unit.
(off)
The power synchronized unit is off.
(on)
After the power synchronized unit is turned on, the following
condition for powering on the ETERNUS DX/AF is detected.
AC output from server UPS units using the SENSOR port,
the AC SENSOR port, or the CASCADE port
(blinks)
Even though the power synchronized unit is turned on, the
following condition for powering on the ETERNUS DX/AF is
not detected.
- AC output from server UPS units using the SENSOR
port, the AC SENSOR port, or the CASCADE port
The power synchronized unit is starting up.
POWER SEN-
SOR
(green)
Displays that the power
synchronized unit has
commanded the ETER-
NUS DX/AF to turn on
or off.
(off)
The following condition is not detected and the power syn-
chronized unit commands the ETERNUS DX/AF to turn off.
AC output from server UPS units using the SENSOR port,
the AC SENSOR port, and the CASCADE port
(on)
The following condition is detected and the power synchro-
nized unit commands the ETERNUS DX/AF to turn on.
AC output from server UPS units using the SENSOR port,
the AC SENSOR port, or the CASCADE port
POWER CON-
TROL
(green)
Displays the power sta-
tus of the ETERNUS DX/
AF.
(off)
All of the ETERNUS DX/AF storage systems are off.
(on)
The ETERNUS DX/AF is on.
(blinks)
The ETERNUS DX/AF is still on even after the power synchro-
nized unit commands the ETERNUS DX/AF to turn off (such as
when shutting down the ETERNUS DX/AF).
CHECK
(Yellow)
Displays the starting
status of the power
synchronized unit.
(off)
The power synchronized unit is operating normally.
(on)
The power synchronized unit is starting up.