BX920 S2 Operating Manual 77
Server menu
Event Log Full Mode
Specifies the Event Logging mode.
Maintain
Event Logging is stopped as soon as the SEL (System Event Log)
is full.
Overwrite
Event Logging continues despite the SEL being full. The oldest
entry is overwritten.
SDRR Version
Shows the SDRR version number.
LAN Settings
Calls a submenu for specifying the LAN parameters for the iRMC (see
page 77).
IPMI Status
Calls a submenu for displaying information on the IPMI controller (see
page 78).
6.8.5.1 LAN Settings
Service LAN
Specifies whether communication between a remote system and the
local iRMC is possible (Enabled) or not (Disabled).
Service LAN Port
Specifies which LAN port (LAN 1, LAN 2) of the iRMC
service LAN is used. The iRMC uses the selected service LAN port for
communication. The iRMC uses the system LAN port for communication.
I This item is only hidden if "Service LAN" is set to Disabled.
DHCP
Specifies whether DHCP support for the iRMC is activated (Enabled) or
not (Disabled). It is recommended to use the same settings as those used
for the network card.
I This item is only hidden if "Service LAN" is set to Disabled.