RX2510 M2 Operating Manual 59
Starting up and operation
Ê Follow the on-screen instructions (see also section "Configuring the 
server and installing the operating system with the ServerView 
Installation Manager" on page 63 or section "Configuring the server and 
installing the operating system without the ServerView Installation 
Manager" on page 64).
– System already installed:
Ê Press the On/Off button.
The server is switched on, performs a system test and boots the 
operating system.
I In the case of configurations with a large memory size, the boot 
process may be prolonged and the screen may remain dark for 
several minutes.
Switching the server off
The Power-on indicator (see figure 5 on page 49) lights up green.
Ê Shut down the operating system properly.
The server is switched off automatically and enters standby mode. The power-
on indicator lights up orange.
I If the operating system does not switch off the server automatically, press 
the On/Off button for at least four seconds and/or send a corresponding 
control signal for power button override.
Other On/Off options
Besides the On/Off button, the server can be switched ON and OFF in the 
following ways:
– Timer-controlled switch-on/off
Using the ServerView Operations Manager or iRMC S4, you can configure 
that the server is switched on/off controlled by an internal timer.
– Ring indicator
The server is switched on by an internal or external modem. 
– Wake up On LAN (WOL)
The server is switched on by a command via the LAN (Magic Packet™).