EasyManua.ls Logo

Fujitsu ServerView Event Manager - RAID Adapter Traps (Megaraid.mib)

Fujitsu ServerView Event Manager
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ServerView Event Manager 127
Trap overview
5.3.15 RAID Adapter traps (Megaraid.mib)
MIB-OID: 1.3.6.1.4.1.16.1.1.200
This section lists RAID Adapter traps in alphabetical order.
Trap name ID Meaning Error class
rtBatteryMissing 9020 Adapter-%d: Battery
Module is missing.
informational
rtBattery
TemperatureHigh
9022 Adapter-%d: Battery
Module temperature
exceeded Danger
Threshold.
informational
rtBatteryVolatageLow 9021 Adapter-%d: Battery
Module voltage is low.
informational
rtCheck
ConditionStatus
9018 Adapter-%d, Channel-%d,
Target-%d: Command
completed with Sense_Key-
0x%x ASC-0x%x ASCQ-
0x%x.
informational
rtCheck
ConsistencyAborted
9010 Adapter-%d, Logical Drive-
%d: Check consistency
aborted by user.
informational
rtCheck
ConsistencyCompleted
9009 Adapter-%d, Logical Drive-
%d: Check Consistency
completed. No
inconsistencies found.
informational
rtCheck
ConsistencyFailed
9012 Adapter-%d, Logical Drive-
%d: Check consistency
failed.
informational
rtCheck
ConsistencyStarted
9008 Adapter-%d, Logical Drive-
%d: Check consistency
started.
informational
rtConfigUpdated 9001 Adapter-%d: A new
configuration has been
written.
informational
Table 38: RAID Adapter traps

Table of Contents

Related product manuals