Alarm configuration example
4.12 Alarm configuration example
This section explains a typical example of alarm configuration.
Purpose
When an event whose severity is critical occurs on the ALARMTEST server, a
mail is sent to the administrator (admin@test.co.jp).
Requirements
ServerView agent is running on the server, and the server is registered as a
management target in ServerView Operations Manager on the same
network.
Test traps from the ServerView agent to ServerView Operations Manager
are functioning normally.
ServerView Operations Manager can access the SMTP server
(111.222.3.20) while it is in operation.
Setting procedure
Ê Perform one of the following operations.
When operating from the ServerView Operations Manager start window:
Click Alarm Configuration.
When operating from the individual function windows:
Click Event Management Alarm Configuration in the menu bar at the top
of the window.
The Manage Alarm Rules window opens.
Ê Click Add.
The New Name dialog box opens.
Ê Enter e.g. CriticalMail in the New Name dialog box and click OK.
Ê Click Apply, then click Next.
The Assign Servers window opens.
Ê Select the ALARMTEST server in the server list, and click the > button.