EasyManua.ls Logo

Fujitsu ServerView Event Manager - Page 31

Fujitsu ServerView Event Manager
172 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ServerView Event Manager 31
iRMC S2/S3 SEL Entries and SC2 MIB Traps
07000A ’PSU XY’: Power
supply critical
temperature
Temperature at
power supply ’PSU
XY’ in cabinet XY of
server XY has
reached the critical
level.
2037 sc2TrapPower
SupplyCritical
Temperature
07000F ’PSU XY’: Power
supply fan prefailure
Fan failure is
predicted at power
supply ’PSU XY’ in
cabinet XY of server
XY.
2038 sc2TrapPower
SupplyFan
Failure
Prediction
0C0004 ’CPU XY’: CPU
internal error (IERR)
Internal error (IERR)
occurred on CPU
’CPU XY’ in cabinet
XY of server XY.
2082 sc2TrapCpu
Ierr
0C0021 ’CPU XY’:
Uncorrected CPU
Machine Check
Architecture (MCA)
error
0C0007 ’CPU XY’: CPU clock
automatically
throttled
CPU speed at server
XY changed to XY
percent of its
maximum speed.
2080 sc2TrapCpu
Speed
Changed
0C0017 ’CPU XY’: CPU
failure predicted
CPU failure is
predicted for CPU
’CPU XY’ in cabinet
XY.
2081 sc2TrapCpu
Prefail
0C000B ’CPU XY’: CPU
disabled
CPU ’CPU XY’ in
cabinet XY of server
XY is disabled.
2083 sc2TrapCpu
Disabled
Error
code
iRMC S2/S3 SEL
entry
Trap text Trap
no.
Trap name
Table 4: iRMC S2/S3 SEL entry - SC2 MIB trap

Table of Contents

Related product manuals