AP6.3 Setting
6. Set items in AIS parameter setting menu as shown in the table below. (Select screened
parameters.)
Item Setting Remarks
NO
Connected
YES
A-Adapter 1 to 16 Set the port number to which AIS is connected.
IEC61162-2
(38400 bit/s)
Device
interface
IEC61162-1
(
4800 bit/s
)
Normal IEC61993-2
Device mode
A
llow ille
g
al values
Not used IEC61162-1
Transmit
Checksum
Used
$Char not included
(IEC61162-1 or2)
Checksum
$Char included
(Some old NMEA)
7. Move the cursor onto [OK] and press [SELECT] to return to “Installation
parameters” window.
8. Move the cursor onto [OK] and press [SELECT] to show “SIO Booting”.
9. Remove the “Key disk” from the floppy disk drive.
AP6-11