3. SETTINGS AND ADJUSTMENTS
3-6
3.4 How to Enable or Disable Alerts
You can enable or disable alerts from the [ALERT ENABLE] menu. Disabling an alert
in this menu will disable all related alerts for the disabled alert.
Note: All alerts are set to [ENABLE] by default.
1. Access the [INITIAL SET] menu, following the procedure outlined in "How to ac-
cess the [INITIAL SET] menu" on page 3-1.
2. Select [ALERT ENABLE], then press the ENT/ACK key.
Active/unacknowledged alerts are displayed with an alert icon next to the alert ID.
3. Select an alert, then press the ENT/ACK key to enable or disable the alert.
Enabled alerts are displayed in green color text, disabled alerts are displayed in
gray color text.
4. Press the MENU/ESC key to return to the [INITIAL SET] menu.
ALERT ENABLE
: BACK
: CURSOR
MENU
: ENABLE/DISABLE
ENT
WARNING1 WARNING2
ENABLE
001 014
026
030
029
005
007
009
010
008
011
025
035
032
002
003
004
DISABLE
ENABLE
HI
LO
001 :
TX MALFUNCTION
DISABLE
: 8 : 0 : 0: 9
Cursor selection is highlighted
Selected alert’s details
Disabled alerts are displayed in gray.