3. SETTINGS AND ADJUSTMENTS
3-7
3.5 How to Set Up the I/O Ports
1. Access the [INITIAL SET] menu, following the procedure outlined in "How to ac-
cess the [INITIAL SET] menu" on page 3-1.
2. Select [I/O PORT], then press the ENT/ACK key.
Note: The figure above shows the default settings for all ports.
The available port settings are outlined in the table on the following page.
Note 1: When [MODE] is set to [BEACON] or [MONITOR], speed settings are fixed at
the default setting.
Note 2: For detailed information on data format and related speeds, see "DIGITAL
INTERFACE" on page AP-2.
Mode definitions
PORT MODE SPEED (baud)
COM1 EXT DISPLAY 4800, 38400
LONG RANGE 4800, 38400
BEACON 4800
MONITOR 57600
SERVICE 4800, 38400
DISABLE -
COM2 to COM3 Same as COM1. Same as COM1.
COM4 EXT DISPLAY 4800, 38400
LONG RANGE 4800, 38400
SENSOR 4800, 38400
BEACON 4800
MONITOR 57600
SERVICE 4800, 38400
DISABLE -
COM5 to COM6 Same as COM4. Same as COM4.
SENSOR1 SENSOR Fixed at 4800
DISABLE -
SENSOR2 & SENSOR3 Same as SENSOR1. Same as SENSOR1.
MODE Definition
EXT DISPLAY External display (Radar, ECDIS, Pilot plug, etc.).
LONG RANGE Long range communication device (Inmarsat C, etc.).
SENSOR GPS, Gyrocompass, ROT, etc.
MONITOR For FA-1702 Monitor Unit.
BEACON For Beacon Receiver.
SERVICE For service personnel only. Do not use.
DISABLE Disable the port.
EXT DISPLAY
EXT DISPLAY
EXT DISPLAY
I / O PORT
PORT
COM1
MODE SPEED
38400baud
COM2 EXT DISPLAY
EXT DISPLAY
38400baud
COM3 EXT DISPLAY 38400baud
COM4
SENSOR
SENSOR
SENSOR
38400baud
COM5 38400baud
COM6 38400baud
SENSOR1 4800baud
SENSOR2
4800baud
SENSOR3
4800baud
: SELECT: CURSOR
ENT
: BACK
ENT