1. MOUNTING
1-7
How to install distributor unit DB-1
The length of the cable between the distributor unit and transponder unit is 1 m so lo-
cate the distributor unit within 1 m from the transponder unit. Fix the distributor unit on
the bulkhead, facing the cable entrance downward. Remove the lid of the distributor
unit and secure the unit with two self-tapping screws.
Note: Be sure no foreign material or water enters the distributor unit.
1.2 How to Install the FA-1702 Monitor Unit
The monitor unit can be installed on a desktop, overhead (bulkhead) or flush mounted
in a panel. Install it on the chart table or near the steering place, referring to the outline
drawing.
When selecting a mounting location for the monitor unit, keep the following in mind:
Keep the unit out of direct sunlight.
The temperature and humidity should be moderate and stable.
(Operating temperature range: -15°C to +55°C)
Locate the unit away from exhaust pipes and vents.
The mounting location should be well ventilated.
Mount the unit where shock and vibration are minimal.
Keep the unit away from electromagnetic field generating equipment such as motor,
generator.
For maintenance and checking purposes, leave sufficient space at the sides and
rear of the unit and leave slack in cables. Refer to the outline drawing.
A magnetic compass will be affected if the unit is placed too close to it. Observe the
following compass safe distances to prevent disturbance to the magnetic compass:
Standard compass: 0.65 meters
Steering compass: 0.40 meters
For flush mount installation, make sure the mounting location is flat.
To avoid damage to the cabling when mounting the FA-1702, make sure the cabling
is not excessively bent.
Note: The cabling to the FA-170 should be completed before mounting the unit. See
"How to connect the FA-1702 monitor unit" on page 2-5.
Self-tapping screw
(4x30)

Other manuals for Furuno FA-170