3-4
Entering transducer data by transducer model number
Note 1: If you are continuing from paragraph 3.1 go to step 2.
Note 2: If you have already entered transducer settings and want to reconfirm them turn on the
power while pressing any key.
1. Turn on the power.
2. Press any key to show the following menu.
XDCR SETTING INSTALLATION DEMO
XDCR SELECT : XDCR TYPE
[HIGH] FREQ : --- kHz
TRANSDUCER : -----
TX POWER : MAX
OUTPUT POWER : -- kW
SUPPLY VOLT : -- V
[LOW] FREQ : --- kHz
TRANSDUCER : -----
TX POWER : MAX
OUTPUT POWER : -- kW
SUPPLY VOLT : -- V
[-/+]: Change setting, Turn OFF to exit
Figure 3-4 Installation main menu
3. Press [
] to select [HIGH] FREQ or [LOW] FREQ (whichever is installed), and then press
[+] to show the dialog box. (The appearance of the dialog box depends on the type of
monitor unit used.) The scroll bar at the bottom of the dialog box shows cursor position in
relation to the entire menu.
15 kHz 28 kHz 33 kHz 36 kHz 38 kHz 41 kHz 45 kHz 50 kHz
Scroll bar
4. Press [+] or [-] to select transducer frequency, and then press [
] or [ ] to close the dialog
box.
5. Press [
] to select TRANSDUCER, and then press [+] to open the dialog box. The dialog
box below is for the 200 kHz transducer.
200B-5S (1kW) 50/200-1ST (1kW) 50/200-1T (1 kW) 200 -8/8 (2 kW)
6. Press [+] or [-] to select model number, and then press [
] or [ ] to close the dialog box.
7. To operate the transducer in reduced power (for example, when vessel is in dry dock), press
[
] to select TX POWER, and then press [+] to open the dialog box.