EasyManua.ls Logo

Furuno FCV-295 - 1.2 Power On;Off; 1.3 Adjusting Display Brilliance; 1.4 Selecting a Display

Furuno FCV-295
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1. OPERATION
2
1.2 Power On/Off
Press the [ /BRILL] key to turn on the pow-
er. The unit beeps, the startup screen ap-
pears and then the last-used display is
shown.
To turn off the power, press the [ /BRILL]
key more than three seconds. The time re-
maining until power off is counted down on
the screen.
1.3 Adjusting Display
Brilliance
1. With the equipment powered, press the
[ /BRILL] key momentarily to show the
brilliance adjustment window.
2. Press the [ /BRILL] key to adjust bril-
liance. Continuous pressing changes the
brilliance cyclically.
(01...98...01...). "0" is
the lowest and "9" is the highest.
You can also use W or X for the adjust-
ment.
3. Press the [ENTER] or [MENU/ESC] key
to save the setting and close the window.
(The window is automatically closed if the
brilliance is not adjusted within approx.
six seconds.)
Note: When the power is reapplied after turn-
ing off the equipment with minimum brilliance,
minimum brilliance will be set after the equip-
ment goes through its initial start up. (The
start up screen appears with the maximum
brilliance.) Adjust the brilliance as necessary.
1.4 Selecting a Display
The FCV-295 has seven display modes: low
frequency display, high frequency display,
dual frequency display, low frequency+zoom,
high frequency+zoom, user 1 display, and
user 2 display. Select one with the [MODE]
control as follows:
1. Rotate the [MODE] control to open the
mode selection window.
2. Rotate the [MODE] control to select a dis-
play.
1.4.1 Single frequency display
Low frequency
The lower the frequency of the ultrasonic sig-
nal, the wider the detection area. Therefore,
the low frequency is useful for general detec-
tion and judging bottom condition.
High frequency
The higher the frequency of the ultrasonic sig-
nal, the better the resolution. For this reason
the high frequency is ideal for detailed obser-
vation of fish schools.
Beamwidth
Program No. 0252365-XX.XX
Dual (LF/HF)
( ): Mode indication at the top of the screen
BL: Bottom Lock LF: Low Frequency
BZ: Bottom Zoom HF: High Frequency
MZ: Marker Zoom BD: Bottom Discrimination
LOW frequency zoom mode
(BL-LF, BZ-LF, MZ-LF, BD-LF)
Low frequency single mode (LF)
High frequency single mode (HF)
High frequency zoom mode
(BL-HF, BZ-HF, MZ-HF, BD-HF)
User 1, 2
Low
frequency
High
frequency

Other manuals for Furuno FCV-295

Related product manuals