3. ALARMS
3-6
3.9 Depth Alarm
The depth alarm warns you when the bottom is shallower, deeper within or outside the
depth alarm setting. Requires a depth sensor.
1. Rotate the Course control knob to select [DEPTH ALARM] from the [ALARM]
menu then push the knob.
2. Rotate the Course control knob to select an option then push the knob. For
[OFF], press the MENU key consecutively to close the menu.
[OFF]: Turn the alarm off.
[SHALLOW]: Alarm sounds when depth is less than the set value.
[DEEP]: Alarm sounds when depth is greater than the set value.
[INSIDE]: Alarm sounds when depth is within the depth range set.
[OUT OF RANGE]: Alarm sounds when depth is outside the range set.
3. Rotate the Course control knob to set value.
For [INSIDE] and [OUT OF RANGE], set the upper and lower limits for the alarm.
For [SHALLOW] and [DEEP], set a value.
4. Push the Course control knob to confirm setting.
3.10 Water Temperature Alarm
There are five types of water temperature alarms: [UNDER], [OVER], [INSIDE], [OUT
OF RANGE] and [SHEAR]. Requires a water temperature sensor.
1. Rotate the Course control knob to select [TEMP ALARM] from the [ALARM]
menu then push the knob.
2. Rotate the Course control knob to select an option then
push the knob. For [OFF], press the MENU key consecutive-
ly to close the menu.
[OFF]: Turn the alarm off.
[UNDER]: Alarm sounds when water temperature is less
than the set value.
[OVER]: Alarm sounds when water temperature is higher
than the set value.
[INSIDE]: Alarm sounds when water temperature is within the depth range set.
[OUT OF RANGE]: Alarm sounds when water temperature is outside the range
set.
[SHEAR]: Alarm sounds when the temperature changes over the value set within
a minute.
3. Rotate the Course control knob to set value.
[INSIDE], [OUT OF RANGE]: Set the upper and lower limits for the alarm.
[OVER], [UNDER], [SHEAR]: Set a value.
4. Push the Course control knob to confirm setting.
SHALLOW
DEEP
INSIDE
OUT OF RANGE
OFF
UNDER
OVER
INSIDE
OUT OF RANGE
SHEAR