5. MAINTENANCE, TROUBLESHOOTING
5-11
5.6 Sensor in Use Display
The SENSOR IN USE display provides a comprehensive list of the sensors connected
to your NAVPILOT.
1. In the STBY mode, press the MENU key to show the STBY mode menu.
2. Rotate the Course control knob to select [SENSOR IN USE] then push the knob.
The display shows the source for each data and the equipment identifier number. For
example the source of HDG is the FURUNO PG-700 and its equipment identifier num-
ber is 0019E4. Dashed lines indicate no connection or sensor is not currently active.
MESSAGE
SENSOR IN USE
CONTRAST/BRILLIANCE
SEA STATE: FULL-AUTO
MANUAL PARAMETER
MESSAGE
SENSOR IN USE
SEA STATE: FULL-AUTO
MANUAL PARAMETER
ADVANCED AUTO: ON
OTHER MENU
NAVpilot-700
NAVpilot-711/720
SENSOR IN USE
HDG : PG-700 : 0019E4
STW : PORT1
SOG : NAVNET3 : 000C2F
POS : NAVNET3 : 000C2F
WIND : --------------
DPT : --------------
TEMP: --------------