1. INSTALLATION
1-15
1.5.3 How to fabricate the WAGO connectors
Follow the procedure outlined below to fabricate the WAGO terminal connections.
Note: Two terminal openers are included inside the SC-701. Check that the size of the
opener is correct before use.
Small opener (labeled as “DISP”): For use on connectors for cabling between the
SC-702 and SC-701.
Large opener: For use on the connectors inside the SC-701.
1.5.4 How to connect the Antenna Unit (SC-703/SC-1303)
Connect the LAN cable (included as installation materials; see table below) from the
antenna LAN port to the J3 terminal inside the SC-701.
How to fit the waterproof connector
Follow the procedure below to fit the waterproof connector (included in installation ma-
terials marked with “*” in the above table).
Waterproof connector components
Installation
materials type
LAN cable
Length Shielding
CP20-04300* 30 m Yes
CP20-04310* 40 m Yes
CP20-04320* 50 m Yes
CP20-04330 15 m No
CP20-04340 30 m No
CP20-04350* 15 m No
CP20-04360* 30 m No
Procedure
1. Twist the cores.
2. Press the terminal opener downward.
3. Insert the wire to hole.
4. Remove the terminal opener.
5. Pull the wire to confirm that it is secure.
Press downward.
Terminal opener
WAGO connector
Wire
Twist
Sealing
nut
Clip Sealing Nut Housing RJ plug Washer