Magnus Hedlund Page 10
ADDITIONAL INFORMATION
Timer 1 for motor on (Beeps when counting)
Reset switch: SA – up = Reset timer
. Start switch: SA - down = Start timer
Stop switch: SA – middle = Stop timer
LINKAGE – TIMER (Timer 1)
Alarm = 00:30, Elapsed, Buzzer, One time
Mode = Up
Reset switch, SA = On, Off, Off
Start switch, SA = Off, Off, On
Stop switch, SA = Off, On, Off
F5J: Timer 1 for motor on and Timer 2 for 10 sek after motor off (Speech when counting)
SA – down = Motor on (30 sek countdown) Flight mode = MOTOR ON
SA – middle = Motor off (10 sek countdown)
SA – up = Motor off (“Normal”, default)
LINKAGE – TIMER (Timer 1)
Alarm = 00:30, Remainder, Speech, One time
Mode = Down
Reset switch, SA = On, On, Off
Start switch, SA = Off, Off, On
Stop switch, - -
LINKAGE – TIMER (Timer 2)
Alarm = 00:30, Elapsed, Buzzer, One time
Mode = Down
Reset switch, SA = On, Off, On
Start switch, SA = Off, On, Off
Stop switch, - -