BER Test Setup
The following is required in order to be able to measure BER on the Tweaker Monitoring
Screen:
1. Connect a Radio Communication Testset or equivalent to the DVR Antenna port
and set it up as described below:
Program TX frequency matching the programmed DVR Rx Frequency
PATTERN 1011
MODULATION P25
NAC 293
ALGID 80
MFID 00
TGID 1
SID 000001
2. Set the Test Mode AND P25 Rx Modem Test Test Mode to ‘YES’
3. Lower the Radio Communication Testset transmit level until desired BER
Threshold is observed on the Monitoring screen.