EasyManua.ls Logo

Galcon G.S.I DC - Technical Specifications

Galcon G.S.I DC
42 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
G.S.I DC Installation and Operation Guide
37
4 Technical Specifications
Outputs:
12 field valves, 1 fertilizer (out of the 12 valves), 1 master
Operates 2 wires DC latching solenoids only
Output pulse voltage 17 V DC
Pulse length 200 milliseconds
Inputs:
Rain switch Normally Open or Normally Closed
Pulse water meter
Pulse fertilizer meter
Power source :
4 X 3.6 V Lithium batteries
4 X 1.5 V D-size batteries
7.2 V rechargeable battery
12 V external battery optional
Cellular modem: Quad band GSM modem integrated (GPRS class
10) for operating in all GSM operators globally.
Dimensions: 10.5x24.5x25.5 cm
Operating ambient temperature: -10°C to 60°C, 14°F to 140°F
Maximum wire run from G.S.I DC controller to Galcon solenoids:

Related product manuals