EasyManua.ls Logo

Gantner IDL 101 - Page 50

Default Icon
100 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
IDL 101
FUNCTIONAL DESCRIPTION
48
HB_IDL101_E_V222.doc
Gantner Instruments Test & Measurement GmbH
Digital Status Output, Process-Controlled:
Bild 6.13 Digital status output, process-controlled
I/O 1
status
"0" "1" "0" "1"
signal diagram:
With the process-controlled output of status information the data logger monitors measured values, resp. sensor
variables as to constraints (threshold values). The digital output is set if one or several threshold conditions are fulfilled.
The constraints can be freely defined by the user. The user can also preset the logical signal level (see also the
Configuration Software ICP 100)
.
The distribution voltage of the load can amount from 10 up to 30 VDC (load current max. 100mA). It has to be supplied
externally or picked up by the power supply of the data logger.
The status of the digital output can be scanned as 1/0 information via bus.
Connection Scheme Circui
I/O 01+10..30V
+10..30V
I/O 01
0
V
A
B
R
X
T
X
C
O
M
I
/
O
0
2
I
/
O
0
4
+
1
0
.
.
3
0
V
RS 232RS 485SUPPLY
I
/
O
0
6
I
/
O
0
1
I
/
O
0
3
I
/
O
0
5
INTELLIGENT DATA LOGGER
ADR