SPECIFICATION
HB_IDL101_E_V222.doc
91
Gantner Instruments Test & Measurement GmbH
11.10. Chassis
Material: Aluminium and ABS
Dimensions: L 189 x H 90 x W 83 mm
Weight: 574 g
Protective system: IP 20
Installation type: Snap-on mounting
Mounting rail: 35 mm according to DIN EN 50022
Connections: Plug-in screw terminals
Nom. cross section: max. 1,5 mm² (AWG 16), fine mesh
Strip length: 6 mm
11.11. Circuit
Microprocessor: HITACHI H8
A/D-Converter: 10 Bit
Real Time Clock
Program memory: 128 kbyte Flash-EPROM
Data memory: 512 kbyte RAM
After power failure data storage approx. one week
11.12. Accessories
The
Datalogger IDL 101
possesses a range of accessories which facilitate the rapid, simple mounting of the data logger
and its connection to the power supply in the user's installation. In addition components are available which enable
locally extensive bus structures to be build up. Others enable a larger number of data logger to be connected with one
another. A PC can be connected to a bus via an interface converter or directly (RS-232) to the
Datalogger IDL 101
, so
that the whole system by means of the
Configuration Software ICP 100
can be rapidly installed. To enlarge the number of
channels the modules
ISM 111
,
ISM 112
and
IDL 101
are available.
In detail, the following accessories are available:
ISM 111 Intelligent Sensor Module ISM 111
with 4 multifunctional analog inputs,
4 flexible digital inputs/outputs,
RS 485 fieldbus interface
ISM 112 Intelligent Sensor Module ISM 112
with 4 multifunctional analog inputs,
2 flexible digital inputs/outputs,
1 analog output with PID-controller,
RS 485 fieldbus interface