13-18-609 Page 13
2-1
SECTION 2
INSTALLATION
GENERAL - On receipt of the unit, check for any damage that may have been incurred during transit.
Report any damage or missing parts as soon as possible.
Do not electric weld on the compressor or base; bearings can be damaged by
passage of current.
LIFTING UNIT - Proper lifting and/or transporting methods must be used to prevent damage. Lifting slots
are provided in the base for tow motor use. The unit may also be moved into location by rolling on bars.
Lift compressor package by base only. Do not use other places such as motors,
compressors or discharge manifold piping as lifting points.
The eyebolts or lugs provided on the motors are for lifting the motors only and should
not be used to lift any additional weight. All eyebolts must be securely tightened.
When lifting the motors, the lifting angle must not exceed 15 degrees. Failure to
observe this warning may result in damage to equipment or personal injury.
Compressor, air/oil reservoir, separator chamber and all piping and tubing may be at
high temperature during and after operation.