48 49
ENEN
Technical data
Specification
Standards/directives: IEC 61851-1 and IEC TS 61439-7
Installation: on wall or Garo Wallbox stand
Voltage rating: 230V/400 50Hz
Installation systems: TT, TN and IT systems
Charging type: Mode 3
IP classification: IP44
Mechanical impact
resistance:
IK08
Application temperature: -25
0
C–+40
0
C
Storage temperature: -35
0
C–+55
0
C
Installation height: 0.5–1.5 metres above ground/land to lower edge of
charger.
Weight: around 3 kg including socket
3.8–4.1 kg including cable and connector, single-phase
5,4 kg including cable and connector, three-phase
Technical data
Troubleshooting
Instructions / Troubleshooting
Indication Type of fault Measure
Constant red light The residual-current or
personal protective current
breaker
has been tripped.
Reset. Refer to section on
Resetting the residual-current
or personal protective current
breaker.
Constant yellow light Broken cable Check cable
Flashing yellow light Motor lock socket not in
latched position.
Contact a qualified
electrician
No indication Check supply fuse
If the measure advised does not help, contact a qualified fitter.