8
Using the Chime Feature
Turning on the Chime feature is like having bells on every protected door and window. When this
feature is on, sirens and speakers sound 2 beeps whenever anyone opens a protected door or win-
dow.
The Chime feature works only in Level 1—OFF.
¾
To turn Chime on/off:
1. While in Level 1—OFF, from any touchpad, Press 7 + 1. While the Chime feature is on,
touchpads display, “CHIME IS ON” or “CHIME ON.”
Chime-On-Close
The Chime-On-Close feature works like the regular Chime feature, but in addition to the double
beeps heard upon opening a protected door or window, the system sounds one long beep when
the door or window is closed again.
You can turn the Chime-On-Close feature on or off from the programming menus. Refer to
“Using Programming Menus” for information on programming your system.
Using the Voice Chime Feature
If the installer wired speakers to the Phone Interface and Voice module outputs, you can program
your system to speak the programmed sensor text whenever someone opens a protected door or
window. When this feature is on, speakers announce, “Sensor name open/closed.” You can turn
the Voice Chime feature on or off from the programming menus. Refer to “Using Programming
Menus” for information on programming your system.
Exit and Entry Delay Times
After arming your system, you need time to exit the building so you won’t set off an alarm. Like-
wise, upon returning to your home or business, you’ll need enough time to open the door and get
to a touchpad to disarm the system.
•The Exit Delay is a period of time long enough to let you leave through a designated delay
door after arming the system.
•The Entry Delay is a period of time long enough to let you open and enter through a desig-
nated delay door and get to a touchpad to disarm the system.
Exit Delay Example
Note
Arming to Level 2 will also
cause Exit Delays.
You’re about to go on an errand. You are inside your house and have just armed the system to
Level 3—AWAY.
The interior sirens and touchpads sound three quick status beeps, telling you that the system
accepted the command and has started the Exit Delay time.
During the Exit Delay time, the system sounds one short beep every 4 seconds. Exit the premises
immediately.
During the last 10 seconds of the Exit Delay you’ll hear one short beep every second, warning
you that the Exit Delay is about to expire. When the delay expires, you’ll hear three more quick
status beeps. These beeps indicate that the Exit Delay has ended. Opening an armed door or win-
dow after the Exit Delay has expired will cause an alarm (see Figure 4).
Figure 4. Exit Delay Example
A f t e r a r m i n g ,
y o u ' l l h e a r 3
q u i c k b e e p s .
3 q u i c k s t a t u s
b e e p s s o u n d
w h e n t h e s y s t e m
i s a r m e d .
E x i t D e l a y
B E E P S
D u r i n g t h e E x i t D e l a y ,
y o u ' l l h e a r o n e b e e p
e v e r y f o u r s e c o n d s .

Table of Contents

Other manuals for GE Interlogix 60-792-01-95R

Related product manuals